Product

ÖLFLEX® CLASSIC 100 300/500 V

ÖLFLEX® CLASSIC 100 - flexible PVC cable, colour coded, control cable for various applications, 300/500V, also for YSLY or YY.

  • CPR: Article number choice under www.lappkabel.com/cpr.

  • For nominal voltage U0/U: 450/750V or higher conductor cross-sections see ÖLFLEX® CLASSIC 100 450/750V.

  • Product Description
  • Technical data
  • Note

Benefits


  • Space-saving installation due to small cable diameters.

  • High electrical performance due to 4 kV test voltage.

  • HIgh flexibility due to short-twisted conductor layers.

Application range


  • Plant engineering,Industrial machinery,Heating and air-conditioning systems,Power stations

  • Dry or damp rooms that are subject to medium mechanical loads.

  • For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load.

  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG).

  • High-quality alternative to control cable types YSLY or YY.

Product features


  • Flame-retardant according IEC 60332-1-2.

  • Good chemical resistance, see catalogue appendix T1.

Norm references / Approvals


  • Based on EN 50525-2-51.

  • Based on EN 50525-2-11.

Product Make-up


  • Fine-wire strand made of bare copper wires.

  • PVC insulation LAPP P8/1.

  • Cores twisted in layers.

  • PVC outer sheath, grey (similar RAL 7001).

Technical Information


Classification ETIM 5 ETIM 5.0 Class-ID: EC001578
ETIM 5.0 Class-Description: Flexible cable
Classification ETIM 6 ETIM 6.0 Class-ID: EC001578
ETIM 6.0 Class-Description: Flexible cable
Core identification code Up to 5 cores: colour-coded according to VDE 0293-308, refer to Appendix T9
From 6 cores: ÖLFLEX® colour code, refer to Appendix T7.
Conductor stranding Fine wire according to VDE 0295,
class 5/IEC 60228 class 5.
Torsion movement in WTG TW-0 & TW-1, refer to Appendix T0
Minimum bending radius Occasional flexing: 15 x outer diameter
Fixed installation: 4 x outer diameter.
Nominal voltage U0/U: 300/500 V
Test voltage 4000 V
Protective conductor G = with GN-YE protective conductor
X = without protective conductor.
Temperature range Occasional flexing: -5°C to +70°C
Fixed installation: -40°C to +80°C.
  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.

  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.

  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths.

  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum.

  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).

  • Single lengths for sizes: ≥ 5G50 max. 500 m; ≥ 5G95 max. 400; ≥ 3G120 max. 500 m; ≥ 4G120 max. 300; ≥ 4G185 max. 250 m.

  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.