Product

ÖLFLEX® 440 CP

ÖLFLEX® 440 CP - Screened PUR control cable for indoor and outdoor use - cold flexible, abrasion resistant, flame retardant and halogen-free with VDE certification.

  • The robust multi-purpose control cable.

  • Halogen-free and flame-retardant.

  • VDE-tested and registered.

  • Product Description
  • Technical data
  • Note

Benefits


  • Increased durability under harsh conditions thanks to robust PUR outer sheath.

  • Resistant to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media.

  • Wide temperature range for applications in harsh climatic environments.

  • Additional robustness thanks to inner sheath.

  • Copper braiding screens the cable against electromagnetic interference.

Application range


  • Industrial machinery and machine tools.

  • Very suitable for oily wet areas within machinery and production lines that are subject to normal mechanical stress.

  • Construction machinery.

  • Agricultural equipment.

  • For indoor and outdoor use.

Product features


  • Resistant to oil and drilling fluids according to IEC 61892-4, Appendix D.

  • Abrasion and notch-resistant.

  • Halogen-free and flame-retardant(IEC 60332-1-2).

  • EMC-compliant.

  • Flexible down to -40°C.

Norm references / Approvals


  • VDE reg. no. 6582.

  • Suitable for use in fresh water down to 10 m depth at max. water temperature of +40 °C according to EN 50565-2.

Product Make-up


  • Fine-wire, tinned-copper conductor.

  • Core insulation: TPE.

  • Cores twisted in layers.

  • Special polyurethane outer sheath (PUR).

  • Inner sheath made of TPE.

  • Tinned-copper braiding.

  • Sheath colour: Grey (similar RAL 7001).

Technical Information


Classification ETIM 5 ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Classification ETIM 6 ETIM 6.0 Class-ID: EC000104
ETIM 6.0 Class-Description: Control cable
Core identification code Black with white numbers acc. to VDE 0293-334
Conductor stranding Fine wire according to DIN EN 60228 (VDE 0295), class 5 / IEC 60228 class 5
Minimum bending radius Occasional flexing: 15 x outer diameter.
Fixed installation: 6 x outer diameter.
Nominal voltage U0/U: 300/500 V
Test voltage 3000 V
Protective conductor G = with GN-YE protective conductor
X = without protective conductor.
Temperature range Occasional flexing: -40°C to +90°C
Fixed installation: -50°C to +90°C.
  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.

  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.

  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths.

  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum.

  • Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).

  • * Trade product, no Lapp product.

  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.