Product

ÖLFLEX® TRAY II

ÖLFLEX® TRAY II: UL TC-ER 600V or AWM 1000V, WET 75°C, SUN/ OIL RES I+II, DIR BUR, CSA AWM I/II A/B FT4, PVC power + control cable, 0.6/1 kV, Tray - Exposed Run.

  • Torsion resistant for drip loops.

  • Broad application range (NFPA 70/NEC), NFPA 79 compliance.

  • Outdoor use in USA.

  • Product Description
  • Technical data
  • Note

Benefits


  • Cost-saving, fast installation omitting protection systems.

  • Many certifications/ use types.

  • 75 °C WET Rating + Sunlight Resistant Rating: Outdoor use in the USA.

Application range


  • Industrial machinery, plant engineering in the USA.

  • Unprotected 600V operation on cable tray in the USA, incl. 6 ft. Exposed Run laying sections for version with at least 3 conductors.

  • Compliant with Tool machines: (UL) MTW.

  • Outdoor use and Direct Burial in the USA, per UL 1277.

  • USA Wind Turbine Tray Cable (WTTC) do turbin wiatrowych.

Product features


  • Flame-retardant according to CSA FT4 UL Vertical-Tray Flame Test.

  • Oil-resistant according to UL OIL RES I & II.

  • Water-resistant, UL 75°C WET rating.

  • UV resistant (SUN RES), Ozone resistant.

  • Suitable for torsional applications which are typical for the loop in wind turbine generators (WTG).

Norm references / Approvals


  • USA: (UL) TC-ER [E171371], (UL) MTW [E155920], (UL) WTTC [E323700], Submersible Pump (14 - 2 AWG), (UL) PLTC-ER (18 - 12 AWG) [E216027], (UL) ITC-ER (18 - 12 AWG) [E196134], (UL) DP-1 [E233406], UL AWM (18 - 2 AWG) [E100338].

  • UL OIL RES I/ II, 75°C WET, 90°C DRY, NEC/NFPA 70, NFPA 79.

  • CAN: c(UL) CIC/ TC 600V FT4 [E171371], CSA AWM I/II A/B FT1.

Product Make-up


  • Fine-wire strand made of bare copper wires.

  • Insulation: PVC+nylon sheath (PA skin).

  • Outer jacket: Specially formulated thermoplastic polymer.

  • Color of the outer jacket: Black.

Technical Information


Classification ETIM 5 ETIM 5.0 Class-ID: EC000104
ETIM 5.0 Class-Description: Control cable
Classification ETIM 6 ETIM 6.0 Class-ID: EC000104
ETIM 6.0 Class-Description: Control cable
Core identification code Black with white numbers
Conductor stranding Fine copper wire strands
Torsion movement in WTG TW-0 & TW-2, refer to Appendix T0
Minimum bending radius 2 AWG (33.62 mm2) & smaller: 4 x OD
1 AWG (42.41 mm2) & larger: 6 x OD
Nominal voltage UL/CSA: 600 V (TC, MTW, CIC), WTTC 1000 V
UL/CSA: 1000 V (AWM)
IEC: U0/U = 600/1000 V
Protective conductor G = with GN-YE protective conductor
X = without protective conductor.
Temperature range -40°C (static)/ -25°C (occ. moved) to +90°C (TC) or +105°C (AWM).
  • Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request.

  • Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges.

  • Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths.

  • Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum.

  • Please specify the preferred type of packaging (e.g. 1 x 610 m drum or 8 x 76 m coils).

  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.